NMR Restraints Grid |
Result table
image | mrblock_id | pdb_id | bmrb_id | cing | stage | position | program | type | subtype | subsubtype |
608525 | 5kwp | 30141 | cing | 1-original | 1 | XPLOR/CNS | distance | NOE | simple |
# Restraints file 1: design25pdb.restraints !distance restraints assign (resid 1 and name HG2#) (resid 2 and name HN) 2.975 1.175 1.175 assign (resid 2 and name HA) (resid 3 and name HN) 2.430 0.630 0.630 assign (resid 2 and name HN) (resid 3 and name HA) 3.360 1.560 1.560 assign (resid 3 and name HA) (resid 3 and name HG1#) 2.685 0.885 0.885 assign (resid 3 and name HA) (resid 3 and name HG2#) 2.685 0.885 0.885 assign (resid 3 and name HN) (resid 3 and name HG1#) 3.195 1.395 1.395 assign (resid 3 and name HN) (resid 3 and name HG2#) 3.195 1.395 1.395 assign (resid 3 and name HN) (resid 3 and name HB) 2.840 1.040 1.040 assign (resid 3 and name HN) (resid 18 and name HB#) 3.180 1.380 1.380 assign (resid 3 and name HN) (resid 4 and name HN) 3.205 1.405 1.405 assign (resid 4 and name HA) (resid 5 and name HN) 2.445 0.645 0.645 assign (resid 5 and name HN) (resid 8 and name HB) 3.125 1.325 1.325 assign (resid 5 and name HN) (resid 5 and name HB2) 2.990 1.190 1.190 assign (resid 5 and name HN) (resid 5 and name HB1) 2.990 1.190 1.190 assign (resid 5 and name HN) (resid 6 and name HN) 3.445 1.645 1.645 assign (resid 6 and name HN) (resid 6 and name HB#) 2.675 0.875 0.875 assign (resid 6 and name HN) (resid 7 and name HD1) 3.085 1.285 1.285 assign (resid 6 and name HN) (resid 7 and name HD2) 3.085 1.285 1.285 assign (resid 8 and name HA) (resid 8 and name HG2#) 2.675 0.875 0.875 assign (resid 8 and name HN) (resid 8 and name HG2#) 2.790 0.990 0.990 assign (resid 8 and name HN) (resid 8 and name HG1#) 3.235 1.435 1.435 assign (resid 3 and name HG1#) (resid 19 and name HN) 3.460 1.660 1.660 assign (resid 8 and name HN) (resid 8 and name HB) 2.650 0.850 0.850 assign (resid 5 and name HN) (resid 8 and name HN) 2.915 1.115 1.115 assign (resid 9 and name HN) (resid 9 and name HG2) 3.650 1.850 1.850 assign (resid 9 and name HN) (resid 9 and name HG1) 3.650 1.850 1.850 assign (resid 9 and name HN) (resid 9 and name HB2) 2.735 0.935 0.935 assign (resid 9 and name HN) (resid 9 and name HB1) 2.735 0.935 0.935 assign (resid 8 and name HB) (resid 9 and name HN) 3.165 1.365 1.365 assign (resid 8 and name HG2#) (resid 9 and name HN) 3.260 1.460 1.460 assign (resid 8 and name HG1#) (resid 9 and name HN) 2.720 0.920 0.920 assign (resid 8 and name HA) (resid 9 and name HN) 2.325 0.525 0.525 assign (resid 5 and name HN) (resid 9 and name HN) 3.410 1.610 1.610 assign (resid 9 and name HN) (resid 10 and name HN) 3.590 1.790 1.790 assign (resid 10 and name HA) (resid 10 and name HG2#) 2.640 0.840 0.840 assign (resid 5 and name HN) (resid 22 and name HB#) 3.585 1.785 1.785 assign (resid 10 and name HN) (resid 22 and name HB#) 3.650 1.850 1.850 assign (resid 10 and name HN) (resid 10 and name HB) 2.775 0.975 0.975 assign (resid 9 and name HA) (resid 10 and name HN) 2.465 0.665 0.665 assign (resid 11 and name HA) (resid 18 and name HB#) 2.965 1.165 1.165 assign (resid 2 and name HA) (resid 3 and name HG1#) 3.285 1.485 1.485 assign (resid 2 and name HA) (resid 3 and name HG2#) 3.285 1.485 1.485 assign (resid 10 and name HG1#) (resid 11 and name HN) 3.345 1.545 1.545 assign (resid 10 and name HG2#) (resid 11 and name HN) 3.345 1.545 1.545 assign (resid 11 and name HN) (resid 18 and name HB#) 3.520 1.720 1.720 assign (resid 10 and name HB) (resid 11 and name HN) 3.375 1.575 1.575 assign (resid 10 and name HA) (resid 11 and name HN) 2.365 0.565 0.565 assign (resid 11 and name HN) (resid 12 and name HN) 3.245 1.445 1.445 assign (resid 12 and name HA) (resid 12 and name HD2) 3.025 1.225 1.225 assign (resid 12 and name HA) (resid 12 and name HD1) 3.025 1.225 1.225 assign (resid 12 and name HN) (resid 18 and name HB#) 2.635 0.835 0.835 assign (resid 11 and name HB2) (resid 12 and name HN) 3.160 1.360 1.360 assign (resid 11 and name HB1) (resid 12 and name HN) 3.160 1.360 1.360 assign (resid 11 and name HA) (resid 12 and name HN) 2.375 0.575 0.575 assign (resid 14 and name HA) (resid 16 and name HN) 3.520 1.720 1.720 assign (resid 14 and name HA) (resid 15 and name HD2) 2.535 0.735 0.735 assign (resid 14 and name HA) (resid 15 and name HD1) 2.535 0.735 0.735 assign (resid 16 and name HA) (resid 16 and name HG#) 2.840 1.040 1.040 assign (resid 16 and name HN) (resid 18 and name HB#) 3.395 1.595 1.595 assign (resid 15 and name HG2) (resid 16 and name HN) 2.860 1.060 1.060 assign (resid 15 and name HG1) (resid 16 and name HN) 2.860 1.060 1.060 assign (resid 16 and name HN) (resid 16 and name HG#) 2.860 1.060 1.060 assign (resid 16 and name HN) (resid 17 and name HN) 2.595 0.795 0.795 assign (resid 17 and name HN) (resid 18 and name HB#) 3.420 1.620 1.620 assign (resid 16 and name HG#) (resid 17 and name HN) 2.955 1.155 1.155 assign (resid 18 and name HN) (resid 18 and name HB#) 2.465 0.665 0.665 assign (resid 17 and name HB2) (resid 18 and name HN) 3.055 1.255 1.255 assign (resid 17 and name HB1) (resid 18 and name HN) 3.055 1.255 1.255 assign (resid 17 and name HG#) (resid 18 and name HN) 3.395 1.595 1.595 assign (resid 17 and name HN) (resid 18 and name HN) 2.650 0.850 0.850 assign (resid 19 and name HA) (resid 19 and name HD#) 3.105 1.305 1.305 assign (resid 19 and name HB#) (resid 19 and name HD#) 2.605 0.805 0.805 assign (resid 3 and name HG2#) (resid 19 and name HN) 3.460 1.660 1.660 assign (resid 18 and name HB#) (resid 19 and name HN) 2.645 0.845 0.845 assign (resid 19 and name HN) (resid 19 and name HB#) 2.385 0.585 0.585 assign (resid 19 and name HN) (resid 20 and name HN) 2.850 1.050 1.050 assign (resid 20 and name HA) (resid 20 and name HD#) 2.995 1.195 1.195 assign (resid 19 and name HB#) (resid 20 and name HA) 2.910 1.110 1.110 assign (resid 20 and name HA) (resid 20 and name HG2) 2.960 1.160 1.160 assign (resid 20 and name HA) (resid 20 and name HG1) 2.960 1.160 1.160 assign (resid 19 and name HB#) (resid 20 and name HN) 2.520 0.720 0.720 assign (resid 20 and name HN) (resid 20 and name HG2) 3.260 1.460 1.460 assign (resid 20 and name HN) (resid 20 and name HG1) 3.260 1.460 1.460 assign (resid 19 and name HD#) (resid 20 and name HN) 3.580 1.780 1.780 assign (resid 20 and name HN) (resid 20 and name HD#) 3.650 1.850 1.850 assign (resid 20 and name HG2) (resid 21 and name HN) 3.500 1.700 1.700 assign (resid 20 and name HG1) (resid 21 and name HN) 3.500 1.700 1.700 assign (resid 21 and name HN) (resid 21 and name HB#) 2.460 0.660 0.660 assign (resid 21 and name HN) (resid 21 and name HG2) 3.015 1.215 1.215 assign (resid 21 and name HN) (resid 21 and name HG1) 3.015 1.215 1.215 assign (resid 18 and name HA) (resid 21 and name HN) 3.295 1.495 1.495 assign (resid 20 and name HN) (resid 21 and name HN) 3.055 1.255 1.255 assign (resid 10 and name HG1#) (resid 22 and name HN) 3.165 1.365 1.365 assign (resid 10 and name HG2#) (resid 22 and name HN) 3.165 1.365 1.365 assign (resid 22 and name HN) (resid 22 and name HB#) 2.440 0.640 0.640 assign (resid 21 and name HB#) (resid 22 and name HN) 2.715 0.915 0.915 assign (resid 19 and name HB#) (resid 22 and name HN) 3.550 1.750 1.750 assign (resid 18 and name HA) (resid 22 and name HN) 3.650 1.850 1.850 assign (resid 22 and name HN) (resid 23 and name HN) 2.830 1.030 1.030 assign (resid 22 and name HB#) (resid 23 and name HN) 2.680 0.880 0.880 assign (resid 23 and name HN) (resid 23 and name HG2) 2.985 1.185 1.185 assign (resid 23 and name HN) (resid 23 and name HG1) 2.985 1.185 1.185 assign (resid 23 and name HN) (resid 24 and name HN) 3.005 1.205 1.205 assign (resid 22 and name HB#) (resid 24 and name HN) 3.480 1.680 1.680 assign (resid 24 and name HN) (resid 24 and name HB#) 2.465 0.665 0.665 assign (resid 23 and name HG2) (resid 24 and name HN) 3.440 1.640 1.640 assign (resid 24 and name HN) (resid 24 and name HG2) 3.610 1.810 1.810 assign (resid 23 and name HG1) (resid 24 and name HN) 3.440 1.640 1.640 assign (resid 24 and name HN) (resid 24 and name HG1) 3.610 1.810 1.810 assign (resid 21 and name HA) (resid 24 and name HN) 3.040 1.240 1.240 assign (resid 25 and name HA) (resid 25 and name HD2) 3.595 1.795 1.795 assign (resid 25 and name HA) (resid 25 and name HD1) 3.595 1.795 1.795 assign (resid 25 and name HA) (resid 25 and name HG2) 3.010 1.210 1.210 assign (resid 25 and name HA) (resid 25 and name HG1) 3.010 1.210 1.210 assign (resid 25 and name HN) (resid 25 and name HD2) 3.650 1.850 1.850 assign (resid 25 and name HN) (resid 25 and name HD1) 3.650 1.850 1.850 assign (resid 25 and name HN) (resid 26 and name HN) 3.135 1.335 1.335 assign (resid 23 and name HA) (resid 26 and name HB2) 3.010 1.210 1.210 assign (resid 23 and name HA) (resid 26 and name HB1) 3.010 1.210 1.210 assign (resid 16 and name HA) (resid 19 and name HD#) 3.290 1.490 1.490 assign (resid 25 and name HB1) (resid 26 and name HN) 3.410 1.610 1.610 assign (resid 25 and name HB2) (resid 26 and name HN) 3.410 1.610 1.610 assign (resid 26 and name HN) (resid 26 and name HB2) 2.895 1.095 1.095 assign (resid 26 and name HN) (resid 26 and name HB1) 2.895 1.095 1.095 assign (resid 23 and name HA) (resid 26 and name HN) 3.270 1.470 1.470 assign (resid 3 and name HG1#) (resid 4 and name HN) 3.185 1.385 1.385 assign (resid 3 and name HG2#) (resid 4 and name HN) 3.185 1.385 1.385 assign (resid 3 and name HB) (resid 4 and name HN) 2.740 0.940 0.940 assign (resid 4 and name HN) (resid 4 and name HG2) 3.290 1.490 1.490 assign (resid 4 and name HN) (resid 4 and name HG1) 3.290 1.490 1.490 assign (resid 3 and name HA) (resid 4 and name HN) 2.380 0.580 0.580 assign (resid 15 and name HA) (resid 18 and name HB#) 2.705 0.905 0.905 assign (resid 16 and name HA) (resid 19 and name HB#) 2.775 0.975 0.975 assign (resid 10 and name HA) (resid 10 and name HG1#) 2.640 0.840 0.840 assign (resid 8 and name HA) (resid 8 and name HG1#) 2.575 0.775 0.775 assign (resid 1 and name HA) (resid 1 and name HG2#) 2.660 0.860 0.860 assign (resid 3 and name HG1#) (resid 19 and name HA) 2.855 1.055 1.055 assign (resid 3 and name HG2#) (resid 19 and name HA) 2.855 1.055 1.055 assign (resid 12 and name HB2) (resid 18 and name HB#) 2.715 0.915 0.915 assign (resid 12 and name HB1) (resid 18 and name HB#) 2.715 0.915 0.915 assign (resid 2 and name HA) (resid 18 and name HB#) 3.230 1.430 1.430 assign (resid 12 and name HA) (resid 13 and name HD2) 2.705 0.905 0.905 assign (resid 12 and name HA) (resid 13 and name HD1) 2.705 0.905 0.905 assign (resid 2 and name HN) (resid 2 and name HB#) 2.565 0.765 0.765 assign (resid 2 and name HA) (resid 3 and name HG*) 2.950 1.150 1.150 assign (resid 2 and name HB#) (resid 3 and name HN) 2.835 1.035 1.035 assign (resid 3 and name HN) (resid 3 and name HG*) 2.760 0.960 0.960 assign (resid 3 and name HG*) (resid 4 and name HN) 2.695 0.895 0.895 assign (resid 3 and name HG*) (resid 18 and name HN) 3.555 1.755 1.755 assign (resid 3 and name HG*) (resid 18 and name HB#) 2.700 0.900 0.900 assign (resid 3 and name HG*) (resid 19 and name HN) 2.965 1.165 1.165 assign (resid 3 and name HG*) (resid 19 and name HA) 2.595 0.795 0.795 assign (resid 3 and name HG*) (resid 20 and name HN) 3.620 1.820 1.820 assign (resid 4 and name HN) (resid 4 and name HB#) 2.595 0.795 0.795 assign (resid 4 and name HN) (resid 4 and name HG#) 2.990 1.190 1.190 assign (resid 4 and name HB#) (resid 5 and name HN) 2.845 1.045 1.045 assign (resid 5 and name HN) (resid 5 and name HB#) 2.735 0.935 0.935 assign (resid 5 and name HN) (resid 7 and name HD#) 3.515 1.715 1.715 assign (resid 5 and name HB#) (resid 8 and name HN) 3.570 1.770 1.770 assign (resid 5 and name HB#) (resid 22 and name HB#) 3.055 1.255 1.255 assign (resid 6 and name HN) (resid 7 and name HD#) 2.755 0.955 0.955 assign (resid 6 and name HB#) (resid 7 and name HD#) 2.435 0.635 0.635 assign (resid 7 and name HD#) (resid 8 and name HN) 2.880 1.080 1.080 assign (resid 9 and name HN) (resid 9 and name HB#) 2.480 0.680 0.680 assign (resid 9 and name HN) (resid 9 and name HG#) 3.280 1.480 1.480 assign (resid 9 and name HB#) (resid 9 and name HE#) 2.900 1.100 1.100 assign (resid 9 and name HG#) (resid 10 and name HN) 3.200 1.400 1.400 assign (resid 10 and name HN) (resid 10 and name HG*) 2.860 1.060 1.060 assign (resid 10 and name HA) (resid 10 and name HG*) 2.395 0.595 0.595 assign (resid 10 and name HG*) (resid 11 and name HN) 2.760 0.960 0.960 assign (resid 10 and name HG*) (resid 18 and name HA) 2.740 0.940 0.940 assign (resid 10 and name HG*) (resid 18 and name HB#) 2.615 0.815 0.815 assign (resid 10 and name HG*) (resid 22 and name HA) 2.720 0.920 0.920 assign (resid 10 and name HG*) (resid 22 and name HB#) 3.010 1.210 1.210 assign (resid 11 and name HN) (resid 11 and name HB#) 2.610 0.810 0.810 assign (resid 11 and name HB#) (resid 12 and name HN) 2.795 0.995 0.995 assign (resid 12 and name HN) (resid 12 and name HB#) 2.655 0.855 0.855 assign (resid 12 and name HN) (resid 13 and name HD#) 3.245 1.445 1.445 assign (resid 12 and name HA) (resid 12 and name HD#) 2.770 0.970 0.970 assign (resid 12 and name HA) (resid 13 and name HD#) 2.460 0.660 0.660 assign (resid 12 and name HB#) (resid 12 and name HD#) 2.565 0.765 0.765 assign (resid 12 and name HB#) (resid 13 and name HD#) 3.005 1.205 1.205 assign (resid 12 and name HB#) (resid 14 and name HN) 2.895 1.095 1.095 assign (resid 12 and name HB#) (resid 18 and name HN) 2.930 1.130 1.130 assign (resid 13 and name HG#) (resid 14 and name HN) 3.225 1.425 1.425 assign (resid 13 and name HD#) (resid 14 and name HN) 3.180 1.380 1.380 assign (resid 14 and name HN) (resid 14 and name HB#) 2.720 0.920 0.920 assign (resid 14 and name HN) (resid 17 and name HB#) 3.570 1.770 1.770 assign (resid 14 and name HA) (resid 15 and name HG#) 3.215 1.415 1.415 assign (resid 14 and name HA) (resid 15 and name HD#) 2.315 0.515 0.515 assign (resid 14 and name HB#) (resid 15 and name HA) 3.330 1.530 1.530 assign (resid 14 and name HB#) (resid 15 and name HD#) 2.875 1.075 1.075 assign (resid 14 and name HB#) (resid 16 and name HN) 3.540 1.740 1.740 assign (resid 14 and name HB#) (resid 17 and name HN) 2.925 1.125 1.125 assign (resid 14 and name HB#) (resid 17 and name HB#) 2.585 0.785 0.785 assign (resid 15 and name HG#) (resid 16 and name HN) 2.445 0.645 0.645 assign (resid 15 and name HD#) (resid 16 and name HN) 2.830 1.030 1.030 assign (resid 17 and name HN) (resid 17 and name HB#) 2.405 0.605 0.605 assign (resid 17 and name HB#) (resid 18 and name HN) 2.745 0.945 0.945 assign (resid 19 and name HN) (resid 19 and name HG#) 3.310 1.510 1.510 assign (resid 19 and name HA) (resid 19 and name HG#) 2.745 0.945 0.945 assign (resid 20 and name HN) (resid 20 and name HB#) 2.540 0.740 0.740 assign (resid 20 and name HN) (resid 20 and name HG#) 2.950 1.150 1.150 assign (resid 20 and name HA) (resid 20 and name HG#) 2.710 0.910 0.910 assign (resid 20 and name HB#) (resid 20 and name HG#) 2.010 0.210 0.210 assign (resid 20 and name HB#) (resid 20 and name HD#) 2.710 0.910 0.910 assign (resid 20 and name HB#) (resid 21 and name HN) 2.700 0.900 0.900 assign (resid 21 and name HN) (resid 21 and name HG#) 2.625 0.825 0.825 assign (resid 21 and name HA) (resid 21 and name HG#) 2.760 0.960 0.960 assign (resid 21 and name HG#) (resid 22 and name HN) 3.570 1.770 1.770 assign (resid 23 and name HN) (resid 23 and name HB#) 2.695 0.895 0.895 assign (resid 23 and name HN) (resid 23 and name HG#) 2.690 0.890 0.890 assign (resid 23 and name HA) (resid 26 and name HB#) 2.755 0.955 0.955 assign (resid 23 and name HG#) (resid 24 and name HN) 3.100 1.300 1.300 assign (resid 24 and name HN) (resid 24 and name HG#) 3.255 1.455 1.455 assign (resid 24 and name HG#) (resid 25 and name HN) 3.460 1.660 1.660 assign (resid 25 and name HN) (resid 25 and name HB#) 2.465 0.665 0.665 assign (resid 25 and name HA) (resid 25 and name HD#) 3.215 1.415 1.415 assign (resid 25 and name HB#) (resid 26 and name HN) 3.060 1.260 1.260 assign (resid 26 and name HN) (resid 26 and name HB#) 2.570 0.770 0.770
Contact the webmaster for help, if required. Thursday, May 23, 2024 4:49:39 PM GMT (wattos1)